As a global leader and pioneer in the field of radiation protection and medical suspension systems, MAVIG considers it a major goal and responsibility to offer clinically proven and safe solutions.
The new Image Safely setup is MAVIG’s answer to the request of clinical facilities as well as relevant professional societies (e.g. SCAI) for enhanced radiation protection devices (ERPDs), solutions that provide increased radiation protection while reducing orthopedic injuries [1]. MAVIG’s setup combines several advanced protective systems:

Together, these elements provide seamless coverage while allowing intuitive integration into existing clinical workflows and room setups, especially with existing Portegra®2 ceiling-mounted systems. The resulting Image Safely® Zone provides a wide protection area, enabling a high degree of freedom of movement for both operators and supporting staff. The extended height also offers effective protection for taller personnel, including sensitive areas such as the eye lens.
The latest 2025 data, presented at TCT in San Francisco [2], confirm the effectiveness and safety of the Image Safely® setup.
The system achieves up to 98% scatter radiation reduction compared to no shielding, with additional protection of up to 81.4% compared to standard shielding.
“The combined protective effect of the Image Safely Shielding Setup allows medical staff to wear clothing with a lower lead equivalent value – taking the burden of their shoulders.“
–Susan Maguire, Group Chief Physicist Radiation Protection Advisor and Medical Physics Expert, Mater Private Network, Ireland
The “Image Safely” system has been presented at leading international trade shows and conferences around the world, such as SCAI, TCT, RSNA, and WHX (formerly Arab Health), and has received consistently very positive feedback from the clinical community.

❱❱ Complete room solution
❱❱ Weight reduction of protective clothing
❱❱ Up to 98% scattered-radiation reduction
❱❱ Fast and intuitive integration into clinical routine
❱❱ Easy integration into existing rooms with Portegra®2
❱❱ All components are fully compatible and collision‑free in use
Since 1921, MAVIG has set the standard for medical radiation protection “Made in Germany.” With Image Safely, we demonstrate once again our commitment to scientifically proven safety, innovation, and user-oriented design.
[1] Nathaniel R. Smilowitz, et al. (2013): Occupational hazards of interventional cardiology – ScienceDirect, https://doi.org/10.1016/j.carrev.2013.05.002
[2] Maguire S. et al. (2025): Evaluation of a Prototype Ceiling-Mounted Radiation Shield for Simultaneous Radiation Dose Reduction and Ergonomic Impact in Interventional Cardiology, TCT 2025.